Container Type 60hz 1000kva Cummins Power Generator Stamford Alternator

1 SET
MOQ
Container Type 60hz 1000kva Cummins Power Generator Stamford Alternator
Features Gallery Product Description Request A Quote
Features
Specifications
Generator Type: 40 Foot Container Canopy
Engine Model: Cummins KTA38-G9
Alternator: ORIGINAL STAMFORD
Controller: DEEPSEA 7320
Fuel Tank: 6 Hours At 100% Loading
Certificate: ISO9001/ISO14001/CE/PVOC
Canopy: Standard Shipping Container 40 Foot Container
Option: Air Breaker Cabinet / Battery Charger / Fire Hydrant
High Light:

cummins power generator

,

emergency diesel generator

Basic Infomation
Place of Origin: WUXI city China
Brand Name: GPRO
Certification: ISO9001/ ISO14001 /CE / OEM
Model Number: GP1250CCS
Payment & Shipping Terms
Packaging Details: POLY BAG
Delivery Time: 45 days
Supply Ability: 300 SETS/ MONTH
Product Description

Container Type 60hz 1000kva Cummins Power Generator Stamford Alternator

 

Description:
 

1. Rated power: 1125KVA /900KW

2. Standby power: 1250KVA /1000KW

2. Engine: Cummins / KTA38-G9

3. Alternator: Stamford LVI634F

4. Controller: Deepsea 7320

5. Type: 40 ft container 

 

Applications:

1. Industrial area: real estate, hospital, hotel, bank,construction, factory, oil field, airport, mining, railway
2. Home use: personal use for house, camping, party, etc
3. Telecom, Mobile tower, etc
4. Island, Desert or any place without electricity
5. As for emergency equipment special for natural disasters, such as typhoon, earthquake, heavy snow,
6. Standby power or main power, indoor or outdoor using.

 

 

ABOUT OF STANDBY 1000KW CUMMINS CONTAINER GENERATOR:

 

1. SPECIFICATIONS OF GEN-SET
1.1 Set Model GP1250CCS
1.2 Prime at 50HZ, 40℃ ambient 900kW 1125KVA
1.3 Standby at 50HZ, 40℃ ambient 1000kW 1250KVA
1.4 Rated Gen-set output 230/400V 50Hz
1.5 Rated Relative humidity ≤ 60 %
1.6 Dimension (L×W×H) 120 0×2100×3050mm
1.7 Weight 13000kg
1.8 Fuel consumption 100% prime load 191L/h
1.9 Total heat radiated to ambient 163KW
1.10 Noise Level at 7m (Normal/Super) 85dB
1.11 Structure of Gen-set The Gen-set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set.
1.12 Control system (Optional) Basic control panel or Advanced control panel with automatically start-up function and other function.
2. SPECIFICATIONS OF ENGINE
2.1 Engine Brand Origin Cummins motor
2.2 Engine Model KTA38-G9
2.3 Governor/Class Electrical
2.4 Cylinder NO. 12
2.5 Engine build Vee
2.6 Fuel spray pattern PT direct injection
2.7 start-up method 24V, electric
2.8 Aspiration Turbocharged/Aftercooled
2.9 Cooling mode Radiator cooled (enclose water)
2.10 Bore and stroke 159×159 mm
2.11 Compression ratio 14.5:1
2.12 Displacement 38 L
2.13 Engine Prime Power at 1500rpm 1100KWm
2.14 Engine Standby Power at 1500rpm 1220KWm
2.15 Battery capacity 254A/hr
2.16 Starting/Min temperature 7℃
2.17 Lubrication oil capacity 135L
2.18 Coolant capacity - radiator and engine (40℃) 308L
2.19 Exhaust temp - full load prime 499℃
2.20 Exhaust gas flow - full load prime 10663m 3/h
2.21 Exhaust gas back pressure max 76mmHg
2.22 Air flow - radiator (40℃ ambient) 15 m 3/s
2.23 Pusher fan head (duct allowance) 40℃ 13mmH 2O
2.24 Air intake - engine- full load prime 4104m 3/h
2.25 Standard Air intake temp 25℃
2.26 Fuel type #0 Diesel (Natural temperature)
2.27 Filter system Adopt whole changeable lubricating oil, fuel filter and air filter
2.28 Exhaust system Adopt industrial high efficiency muffler and ripple pipe
3. SPECIFICATIONS OF ALTENATOR
3.1 Alternator Model original Stamford/ LVI634F
3.2 Alternator Type A.C. Synchronous
3.3 Rated Voltage 230/400V
3.4 Rated Frequency 50HZ
3.5 Rated speed 1500 RPM
3.6 Voltage regulation mode Auto
3.7 Alternator voltage regulation ±0.5%
3.8 Exciting mode Brushless self exciting
3.9 Power factor 0.8 (lagging)
3.10 Phase & wires 3 phase 12 wires
3.11 Rated currency 1443.4A
3.12 Efficiency 0.942
3.13 Insulation class H
3.14 Protection class IP23
3.15 Single load step to NFPA110 100%
3.16 Standards IEC34-1
3.17 Max. Ambient Temperature 40℃
3.18 Min. Ambient Temperature - 20℃
3.19 Max. altitude 1000m
3.20 Weight 2190kg

 

Container Type 60hz 1000kva Cummins Power Generator Stamford Alternator 0

ATS-Automatic Transfer Switch, when the city power supply failure, the genset will be running automatically within few minutes.

Our normal ATS is bulit inside,but outside ATS box is optional

 

Container Type 60hz 1000kva Cummins Power Generator Stamford Alternator 1

Testing Items of GPRO Genset:
1) Parts fault testing
2) Fue tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insultion testing
6) Noise testing
7) Loading testing: All qualified generator sets are subjected to a comprehensive performance test which inclides 0% load, 25% load, 50% load, 75% load, 100% load and 110% load and to check, verify that all control systems, alarm and shut-own protection.

 

Company Details:

Wuxi Gpro Power Solution Co., Ltd is focusing on power generator products and service in China.Being in the power generation field for more than 10 years, we have very good connection with G-Drive Engines and brand alternators. We are not only assembling the generator set, but alsogiving you the best solution to meet your special needs on projects and your clients.

 

Our advantages:
1.Inspection
1) Each engine shall be tested at manufacturer’s workshop to certify the engine output according to present standard and fuel consumption in accordance with the site operating condition specified by purchaser on the specification datasheet.
2) All relevant information drawings pertinent to the testing and test procedure shall be transmitted to the purchaser in advance of the test date notification.
3) All accompanied documents are corresponding to the actual situation of generators, including the Qualified Certificate, Parameters and the Performance Index.

 

2.Guarantee:
1) Guarantee Period: One year or 1000 running hours, depends on whichever comes first.
2) During the guarantee period, the spare-parts will be sent through your shipping agency in China.
3) Spare-parts can also be sent by air express.